Revolution SLCX400/2-3
ATEX Long Cased Axial Flow Fan
ATEX Construction Code: Ex h IIB+H2 T4 Gb
- Standard size 400 mm
- Air volume flow rates up to 2.601 m3/s
- Static pressure up to 450 Pa
- Suitable for operating temperatures up to +40℃
- Suitable for extract or supply systems
- Available in AC
SKU: SLCX400/2-3
Out of stock
Got a question about this product?
Email us or call us on +44 (0) 1384 275800
Compatible Accessories
Overview
A range of ATEX rated duct mounted axial fans, manufactured in heavy gauge sheet steel. These units are designed to meet the requirements for Hazardous Areas with carbon filled anti-static impeller blades and protection to Ex h IIB+H2 T4 Gb.
Features and Benefits
Intelligent Design
Classified for constructional safety and the requirements stated in 2014/34/EU directive, Gas, Zone and ignition temperature protection to Ex h IIB+H2 T4 Gb.
Efficient Performance
Adjustable pitch aerofoil section impellers with blades made from high quality carbon filled anti-static material for enhanced performance. Hubs are die cast aluminium.
Warranty
Each SLCX has a 12 month warranty.
Specification
Casing
The all metal fan casing and guard provide a long lasting and robust construction. The units have been constructed from a single sheet of steel, with both motor and axial impeller mounted within the length of the unit casing. All casing parts are heavy gauge mild steelsheet, roll formed and welded, then hot dip galvanised to BS EN ISO 1461:2009after fabrication.
Motors
Motors according to Gas Zone, Ignition Temperature and Protection to Ex h IIB+H2 T4 Gb.
Impellers
Adjustable pitch aerofoil impellers are provided with blades made from high quality carbon filled anti static material. Impellers are factory set at an angle to provide maximum performance. Hubs are manufactured from die cast aluminium alloy (LM24). Assembled impellers are dynamically balanced to ISO 14694 Grade G6.3.
Quality Management
Units are to be designed and manufactured with procedures as defined in BS EN ISO 9001. All Revolution SLCX units are to be tested to ISO 5801:1997 (airside performance) and BS 848 Part 2: 1985 (sound performance).
Typical Applications
Chemical and Petrochemical Plants
Chemical and Petrochemical PlantsDust Collection and Suppression
Dust Collection and SuppressionGas Turbine Enclosures
Gas Turbine EnclosuresRefrigerated Stores
Refrigerated StoresWater Treatment Plants